
axismd.ai
Heidenhain Controller
Safety · Intermediate · 30-120 minutes
HEIDENHAIN 330-00BA - MC error in the cut-out channel STO.A.x (-STO.A.P.x=1)
HEIDENHAIN alarm 330-00BA indicates a failure in the Safe Torque Off (STO) safety circuit for axis channel A, where the power stage acknowledgment signal does not match the expected state. This typically occurs when the drive inverter fails to report proper readiness status or when safety circuit components malfunction.
HEIDENHAIN 330-00BA - MC error in the cut-out channel STO.A.x (-STO.A.P.x=1)
MC error in the cut-out channel STO.A.x (-STO.A.P.x=1)
The cutout channel test detected a fault in the safety pulse deletion or release circuit. This affects the STO safety function.
Root Cause Summary
HEIDENHAIN alarm 330-00BA indicates a failure in the Safe Torque Off (STO) safety circuit for axis channel A, where the power stage acknowledgment signal does not match the expected state. This typically occurs when the drive inverter fails to report proper readiness status or when safety circuit components malfunction.
Safety
Causes and Fixes
Check Drive Status Display
Navigate to MOD > DIAGNOSIS > DRIVE and check the status of the affected axis drive for fault codes or readiness indicators.
Look specifically for RDY signal status and any internal drive faults that prevent proper power stage operation.
Verify Drive Power Supply
Check DC bus voltage and motor power supply connections to the drive inverter. Measure voltage levels at the drive terminals.
Ensure proper lockout/tagout procedures before checking electrical connections.
Reset Drive and Monitor
Power cycle the drive inverter and monitor the RDY.x signal transition during startup sequence using the TNC diagnostic display.
Document the exact timing of when the RDY signal fails to prevent troubleshooting loops.
Check Drive Parameters
Verify drive-specific safety parameters and STO configuration settings in the drive's internal parameter set.
Compare current parameters with backup or commissioning documentation to identify any changes.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.