axismd.ai
Heidenhain Controller
Overtravel/Limit · Intermediate · 30-120 minutes
Heidenhain 320-0FB8 - W/o limit switches
HEIDENHAIN alarm 320-0FB8 'W/o limit switches' indicates the TNC control has detected movement or positioning attempt on an axis that lacks properly configured or functioning limit switches. This safety-related alarm prevents potential machine damage by ensuring all axes have active limit switch monitoring before allowing motion commands.
Heidenhain 320-0FB8 - W/o limit switches
W/o limit switches
Heidenhain error 320-0FB8: W/o limit switches. A PLC or machine logic error has been detected. The machine's programmable logic controller has reported a fault that prevents normal machine operation.
Root Cause Summary
HEIDENHAIN alarm 320-0FB8 'W/o limit switches' indicates the TNC control has detected movement or positioning attempt on an axis that lacks properly configured or functioning limit switches. This safety-related alarm prevents potential machine damage by ensuring all axes have active limit switch monitoring before allowing motion commands.
Safety
Causes and Fixes
Check limit switch wiring
Inspect all limit switch connections at the machine interface and verify continuity using multimeter. Check X16 connector pins for loose connections.
Ensure machine power is OFF before checking electrical connections
Test limit switch operation
Navigate to MOD > Machine Parameters > Input/Output and monitor limit switch status in real-time while manually actuating each switch.
Use the TNC's diagnostic screen to see live I/O status rather than relying on external meters
Verify switch mounting
Inspect physical mounting of limit switches for looseness, misalignment, or mechanical damage that could prevent proper actuation.
Replace faulty switches
Replace any switches showing intermittent or no signal response, ensuring proper NC/NO configuration matches machine parameter settings.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.