HEIDENHAIN 280-0602 - Error in tool measurement configuration
This alarm indicates the TNC control cannot properly initialize or validate the tool measurement system due to incomplete, invalid, or inconsistent configuration data. The control requires all probe geometry, type definitions, and calibration parameters to be correctly specified in both the tchprobe.tp table and relevant machine parameters before tool measurement cycles can execute.
HEIDENHAIN 280-0602 - Error in tool measurement configuration
Error in tool measurement configuration
Tool measurement configuration is incorrect or incomplete, preventing proper measurement functions.
Root Cause Summary
This alarm indicates the TNC control cannot properly initialize or validate the tool measurement system due to incomplete, invalid, or inconsistent configuration data. The control requires all probe geometry, type definitions, and calibration parameters to be correctly specified in both the tchprobe.tp table and relevant machine parameters before tool measurement cycles can execute.
Safety
Causes and Fixes
Access touch probe configuration
Press MOD key, enter code if required, navigate to Touch Probe Configuration or System Configuration > Touch Probes to view the current probe table (tchprobe.tp).
On iTNC 530 and TNC 620/640, the path is typically MOD > Settings > Touch Probe > Tool Touch Probe Configuration.
Verify probe table completeness
Check that the TT probe entry exists with probe number (typically probe 1 or 2), probe type (e.g., TT 140), and all geometry fields (center offset X/Y/Z, stylus radius, stylus length) are populated with numerical values, not empty or zero.
Do not modify probe geometry values unless you have accurate calibration data or plan to recalibrate immediately.
Restore or re-enter probe data
If entries are missing or corrupted, restore from a known good backup of tchprobe.tp from the TNC:\system\tchprobe.tp directory, or manually re-enter probe configuration data according to machine documentation.
Always maintain backup copies of tchprobe.tp after successful calibration, stored on external media or network location.
Recalibrate the TT probe
Execute the tool touch probe calibration cycle (typically CYCLING DEF 30 or via the Calibrate Tool Touch Probe menu option) to regenerate valid configuration data and verify probe functionality.
Ensure adequate clearance and proper setup gauge is in position before running calibration cycle.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.