Heidenhain codes
HeidenhainPower SupplyIntermediate30-120 minutes

280-07E4

Heidenhain 280-07E4 - Dresser not defined

Dresser not defined

Heidenhain TNC error 280-07E4: Dresser not defined. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 280-07E4 occurs when the grinding cycle attempts to reference a dresser tool that has not been properly captured or defined for the current grinding wheel. This typically happens during wheel dressing operations when the dresser position data is missing or corrupted in the tool table.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access tool table

    Press MOD key, select 'Tool table' from machine parameters menu to view current tool definitions.

    Check if dresser tool number matches the one called in your grinding cycle

  2. 2

    Verify dresser tool entry

    Locate dresser tool number in table and confirm LENGTH and RADIUS columns contain measured values, not zeros.

    Never manually enter dresser dimensions without proper measurement

  3. 3

    Perform tool measurement

    Use TOOL CALL command followed by tool measurement cycle to capture dresser geometry and position relative to wheel.

    Use cycle 31 TOOL MEASUREMENT for automatic dresser capture on equipped machines

  4. 4

    Validate dresser data

    Return to tool table and verify all dresser parameters are populated with non-zero values before attempting dressing cycle.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Machine parameter access restricted
  • ·Repeated tool measurement failures
  • ·Hardware tool measurement system malfunction

Prevention

  • Establish regular tool table backup procedures
  • Implement standardized dresser measurement protocols
  • Document wheel-dresser associations for each setup
  • Verify tool calls during program development

Common Mistakes

  • Assuming dresser is captured when tool table shows zero values
  • Using wrong tool number in wheel management
  • Skipping dresser measurement after wheel changes
  • Not clearing old dresser data before re-measurement