HEIDENHAIN 280-07D3 - Space not released
HEIDENHAIN alarm 280-07D3 occurs when the wheel head location selected for tool insertion has not been properly released by the PLC or tool management system. This typically indicates a communication failure between the TNC control and the tool changer mechanism or incorrect tool table parameters.
HEIDENHAIN 280-07D3 - Space not released
Space not released
The selected location on the wheel head is not released and cannot accept a grinding wheel.
Root Cause Summary
HEIDENHAIN alarm 280-07D3 occurs when the wheel head location selected for tool insertion has not been properly released by the PLC or tool management system. This typically indicates a communication failure between the TNC control and the tool changer mechanism or incorrect tool table parameters.
Safety
Causes and Fixes
Check Tool Table Status
Press TOOL TABLE key, navigate to the problematic location number and verify the STATUS column shows 'FREE' not 'LOCKED' or 'OCCUPIED'.
Use soft key 'SHOW ALL' to display all tool table columns including status flags.
Reset Tool Location Status
In tool table, select the location and press RESET TOOL soft key, then confirm the status changes to 'FREE'.
Ensure no physical tool is actually present in the location before resetting.
Verify PLC Tool Status Signals
Access PLC status via MANUAL mode > PLC soft key, check tool changer input signals for the specific location match the tool table status.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.