260-0208

Heidenhain 260-0208 - Local symbol. Cannot be displayed

Local symbol. Cannot be displayed

Heidenhain TNC error 260-0208: Local symbol. Cannot be displayed. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 260-0208 occurs when the TNC control cannot display a local symbol due to invalid or corrupted symbol definitions in the PLC program or symbol table. This typically happens when PLC operands are incorrectly defined, missing from the symbol table, or when there's a mismatch between the PLC program and the loaded symbol definitions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access PLC Symbol Management

    Press MOD key, select 'PLC' menu, then navigate to 'Symbol table' to check current symbol definitions.

    Always backup the working symbol table before making changes

  2. 2

    Verify Symbol Table Integrity

    Check for corrupted entries, missing operand definitions, or syntax errors in the symbol table display.

    Do not modify symbol table without proper PLC program documentation

  3. 3

    Reload Symbol Table

    If corruption is found, reload the correct .SYM file from backup or regenerate from the PLC source code using the PLC programming software.

  4. 4

    Verify PLC Program Compatibility

    Ensure the loaded PLC program version matches the symbol table version by checking timestamps and version numbers in the PLC status display.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC program source code is not available
  • ·Memory parameter changes don't resolve the issue
  • ·Multiple related PLC alarms persist after troubleshooting

Prevention

  • Maintain backup copies of working PLC programs and symbol tables
  • Document all PLC modifications with version control
  • Regularly verify PLC memory usage doesn't exceed 80% capacity

Common Mistakes

  • Loading PLC programs without corresponding symbol tables
  • Modifying symbol definitions without updating the PLC program
  • Ignoring PLC compilation warnings during program loading

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.