Heidenhain codes
HeidenhainProgram/G-codeIntermediate30-120 minutes

280-044D

HEIDENHAIN 280-044D - Meas. pos. not in traverse range

Meas. pos. not in traverse range

The defined measurement position is outside the rotary axis's valid traverse range.

Root Cause Summary

Alarm 280-044D occurs when a measured position value from a rotary axis probe cycle or manual measurement falls outside the defined traverse range limits in the axis parameters. This typically happens during touch probe operations on rotary axes where the measured angle exceeds the configured software limits.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check current axis limits

    Access MOD function, select 'Machine parameters', navigate to axis-specific parameters and check MP1510 and MP1520 values for the rotary axis.

    Document current values before making changes for rollback purposes

  2. 2

    Verify measurement position

    Check the actual measured position in the measurement protocol or current position display to confirm it exceeds the software limits.

    Ensure the measured position is mechanically safe before expanding limits

  3. 3

    Adjust software limits

    Modify MP1510 and MP1520 to accommodate the measured position, ensuring adequate safety margin beyond the measurement value.

    Consider the full range of part geometries that may be measured in the future

  4. 4

    Reset and verify

    Perform control reset (CTRL+ALT+DEL) to activate new parameters and repeat the measurement cycle to confirm alarm clearance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder hardware failure suspected
  • ·Mechanical axis binding or damage
  • ·Multiple related servo alarms persist after parameter corrections

Prevention

  • Regularly verify rotary axis software limits match actual mechanical range
  • Document and validate all probe cycle parameters before production use
  • Maintain accurate encoder calibration records

Common Mistakes

  • Confusing degrees and radians in rotary axis parameters
  • Forgetting to reset control after parameter changes
  • Not accounting for coordinate system rotations in measurement calculations

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.