HEIDENHAIN 231-C4D0 - C4D0 Error in torque constant
This alarm fundamentally indicates that the TNC control cannot validate or accept the configured torque constant for the motor, which is essential for field-oriented control calculations. The torque constant relates motor current to produced torque and must be accurately defined for proper servo performance. The issue stems from either incorrect parameter configuration, corrupted data, or communication failure during parameter initialization between the TNC and the drive system.
HEIDENHAIN 231-C4D0 - C4D0 Error in torque constant
C4D0 Error in torque constant
The torque-constant value for the named drive is invalid (zero or above 9999). The manual ties this to the motor data in Motor.mot, for example implausible no-load voltage values.
Root Cause Summary
This alarm fundamentally indicates that the TNC control cannot validate or accept the configured torque constant for the motor, which is essential for field-oriented control calculations. The torque constant relates motor current to produced torque and must be accurately defined for proper servo performance. The issue stems from either incorrect parameter configuration, corrupted data, or communication failure during parameter initialization between the TNC and the drive system.
Safety
Causes and Fixes
Access Machine Parameters
Press MOD key, enter service password, select 'Machine Parameters'. Navigate to CfgMotorPara section and locate the affected axis number from the alarm message (%1 indicates axis identifier).
The alarm message %1 will show the specific axis designation (X, Y, Z, etc.) - note this before entering parameters.
Locate Torque Constant Parameter
Find parameter for torque constant (typically labeled as 'motorTorqueConstant' or 'Kt'). Check if value exists and is non-zero. Heidenhain motors typically have Kt values between 0.5 and 3.0 Nm/A depending on motor size.
Never enter estimated values - always use exact nameplate or manufacturer documentation data.
Verify Motor Nameplate Data
Physically inspect the motor nameplate on the affected axis. Record exact model number and all electrical specifications. Cross-reference with Heidenhain motor documentation or LC display specification sheets to obtain correct Kt value.
For LC motors (integrated measuring systems), the motor data is often stored in the EnDat memory - use drive diagnostics to read stored motor parameters directly.
Enter Correct Torque Constant
Input the verified Kt value into the motor parameter field. Ensure units match (typically Nm/A for Heidenhain systems). Save parameters and perform a complete control reboot (power cycle) to reinitialize drive system.
After parameter changes, a COLD start is required - use MOD > Control Configuration > Restart Control for proper initialization.
Call a technician if: