HEIDENHAIN 231-94E0 - 94E0 Switching EnDat 2.2 to 1 Vpp requires reinitialization
Alarm 231-94E0 occurs when the TNC control detects a mismatch between the configured encoder interface type and the actual encoder connected to the drive. This typically happens after encoder replacement or when machine parameters MP720 (encoder type) don't match the physical encoder interface.
HEIDENHAIN 231-94E0 - 94E0 Switching EnDat 2.2 to 1 Vpp requires reinitialization
94E0 Switching EnDat 2.2 to 1 Vpp requires reinitialization
The position encoder interface was switched between EnDat 2.2 and 1 Vpp, so the drive must be reinitialized before the axis can run again.
Root Cause Summary
Alarm 231-94E0 occurs when the TNC control detects a mismatch between the configured encoder interface type and the actual encoder connected to the drive. This typically happens after encoder replacement or when machine parameters MP720 (encoder type) don't match the physical encoder interface.
Safety
Causes and Fixes
Access machine parameters
Press MOD key, select 'Machine parameters', navigate to MP720 for the affected axis using the axis selection softkey.
Always document original MP720 values before making changes
Verify encoder type setting
Check MP720 value - '1' for EnDat 2.2, '0' for 1Vpp. Compare with actual encoder specifications on nameplate or documentation.
Incorrect MP720 setting can damage encoder or drive electronics
Update MP720 parameter
Change MP720 to match installed encoder type. Enter new value and confirm with ENT key.
EnDat encoders typically have 'EnDat' marking on label, 1Vpp encoders show sine wave symbols
Perform drive reinitialization
Execute PLC function 'Initialize drives' from service menu or cycle power to TNC control completely.
Ensure machine is in safe position before drive reinitialization
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.