HEIDENHAIN 231-A021 - A021 Cancelation of brake line test. Guard door open
HEIDENHAIN alarm 231-A021 occurs when guard doors are detected open during the automatic brake control test or brake line test sequence. The TNC system cancels the brake test as a safety precaution since proper enclosure integrity is required during spindle brake verification procedures.
HEIDENHAIN 231-A021 - A021 Cancelation of brake line test. Guard door open
A021 Cancelation of brake line test. Guard door open
This TNC 640 error relates to the motor brake system. The control has detected an issue with brake operation or testing.
Root Cause Summary
HEIDENHAIN alarm 231-A021 occurs when guard doors are detected open during the automatic brake control test or brake line test sequence. The TNC system cancels the brake test as a safety precaution since proper enclosure integrity is required during spindle brake verification procedures.
Safety
Causes and Fixes
Check door interlock status in TNC diagnostics
Navigate to MOD > Service > Diagnosis > PLC and check input status for door interlock switches (typically I0.x inputs).
Use the TNC's real-time I/O display to watch switch states while manually operating door latches.
Verify physical door closure
Ensure all guard doors are fully closed and latched properly. Check door alignment and latch engagement.
Never bypass safety interlocks - repair faulty switches instead.
Test interlock switch continuity
With power off, use multimeter to verify switch contacts change state when door is opened/closed. Check wiring to TNC input terminals.
Common failure points are worn switch actuators and corroded terminals in the door hinge area.
Replace faulty interlock switches
Install new safety-rated interlock switches matching original specifications. Update PLC program if input assignments change.
Use only safety-certified switches rated for the application's safety category.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.