Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

231-9460

HEIDENHAIN 231-9460 - 9460 Configuration of LIFTOFF is not possible

9460 Configuration of LIFTOFF is not possible

This TNC 640 error indicates invalid machine parameter settings. The control has detected configuration data that does not match the hardware setup.

Root Cause Summary

HEIDENHAIN alarm 231-9460 occurs when the spindle LIFTOFF configuration cannot be properly set due to invalid DC voltage parameters in the power supply configuration. This typically results from incorrect entries in the DC link voltage monitoring parameters or power supply limit settings that are outside acceptable ranges for the spindle drive system.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Spindle Parameters

    Navigate to MOD function → Machine Parameters → Spindle Parameters → Power Supply section to locate PowSupplyLimitOfDcVoltage parameter.

    Use parameter search function (CTRL+F) to quickly locate power supply parameters

  2. 2

    Verify Voltage Range

    Check that PowSupplyLimitOfDcVoltage value is within manufacturer specifications (typically 300-800V depending on spindle drive model).

    Never exceed maximum voltage ratings specified in spindle drive documentation

  3. 3

    Correct Parameter Value

    Set PowSupplyLimitOfDcVoltage to appropriate value based on spindle drive specifications and perform parameter reset.

    Document original values before making changes for rollback capability

  4. 4

    Test LIFTOFF Configuration

    Attempt to reconfigure LIFTOFF function through spindle setup menu to verify parameter acceptance.

    Ensure spindle is at complete stop before testing LIFTOFF configuration

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter corruption persists after reset
  • ·Spindle drive hardware fault suspected
  • ·Multiple related alarms appear simultaneously

Prevention

  • Regularly backup machine parameters
  • Document all parameter changes with dates and reasons
  • Verify parameter relationships before making changes
  • Keep spindle drive documentation accessible

Common Mistakes

  • Setting voltage parameters without consulting drive specifications
  • Ignoring parameter logical relationships
  • Making multiple parameter changes simultaneously
  • Not backing up configuration before modifications