HEIDENHAIN 231-9250 - 9250 Motor encoder: EnDat 2.2 not possible
Alarm 231-9250 occurs when the TNC control expects an EnDat 2.2 encoder based on motor table configuration but cannot establish proper EnDat 2.2 communication protocol. This typically results from encoder hardware failure, incorrect motor table parameters, or cable/connection issues preventing the bidirectional digital communication required for EnDat 2.2 protocol.
HEIDENHAIN 231-9250 - 9250 Motor encoder: EnDat 2.2 not possible
9250 Motor encoder: EnDat 2.2 not possible
This TNC 640 error indicates a communication problem on the DRIVE-CLiQ network for the specified axis. The control cannot properly exchange data with the drive components.
Root Cause Summary
Alarm 231-9250 occurs when the TNC control expects an EnDat 2.2 encoder based on motor table configuration but cannot establish proper EnDat 2.2 communication protocol. This typically results from encoder hardware failure, incorrect motor table parameters, or cable/connection issues preventing the bidirectional digital communication required for EnDat 2.2 protocol.
Safety
Causes and Fixes
Access motor table configuration
Navigate to MOD function → Machine Parameters → Channel-specific parameters → Axes → Motor table for the affected axis.
Document current settings before making changes
Verify encoder type parameter
Check parameter for encoder interface type - ensure it matches the physically installed encoder specification from encoder nameplate.
Incorrect encoder type can cause permanent damage to encoder electronics
Correct encoder type setting
If mismatch found, change encoder type parameter to match actual encoder hardware and perform control restart.
Keep encoder documentation handy for reference specifications
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.