Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-9250

HEIDENHAIN 231-9250 - 9250 Motor encoder: EnDat 2.2 not possible

9250 Motor encoder: EnDat 2.2 not possible

This TNC 640 error indicates a communication problem on the DRIVE-CLiQ network for the specified axis. The control cannot properly exchange data with the drive components.

Root Cause Summary

Alarm 231-9250 occurs when the TNC control expects an EnDat 2.2 encoder based on motor table configuration but cannot establish proper EnDat 2.2 communication protocol. This typically results from encoder hardware failure, incorrect motor table parameters, or cable/connection issues preventing the bidirectional digital communication required for EnDat 2.2 protocol.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access motor table configuration

    Navigate to MOD function → Machine Parameters → Channel-specific parameters → Axes → Motor table for the affected axis.

    Document current settings before making changes

  2. 2

    Verify encoder type parameter

    Check parameter for encoder interface type - ensure it matches the physically installed encoder specification from encoder nameplate.

    Incorrect encoder type can cause permanent damage to encoder electronics

  3. 3

    Correct encoder type setting

    If mismatch found, change encoder type parameter to match actual encoder hardware and perform control restart.

    Keep encoder documentation handy for reference specifications

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive amplifier replacement required
  • ·Encoder replacement on critical axis
  • ·Multiple simultaneous encoder failures

Prevention

  • Regular encoder cable inspection
  • Proper cable routing away from interference sources
  • Periodic encoder connection cleaning
  • Monitor encoder supply voltage stability

Common Mistakes

  • Using wrong cable type for EnDat
  • Mixing EnDat versions in motor table
  • Ignoring electromagnetic interference sources
  • Attempting to use damaged cables temporarily

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.