Heidenhain 231-4003 - 4003 EMERGENCY STOP is active (emergency stop test)

4003 EMERGENCY STOP is active (emergency stop test)

Heidenhain error 231-4003: 4003 EMERGENCY STOP is active (emergency stop test). The emergency stop circuit has been activated or an E-stop condition has been detected. All axis motion is immediately halted and cannot resume until the E-stop condition is cleared and the machine is safely reset.

Root Cause Summary

HEIDENHAIN alarm 231-4003 indicates the emergency stop circuit is active during the TNC's automatic emergency stop test sequence. This alarm occurs when the control detects that the E-STOP circuit remains engaged or fails to reset properly during the system's internal safety verification routine.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Visual Inspection of All E-Stop Buttons

    Check all emergency stop buttons on the machine panel, pendant, and any auxiliary stations. Look for buttons that appear pressed in or twisted to the locked position.

    Do not attempt to force stuck buttons - they may be mechanically damaged

  2. 2

    Reset Emergency Stop Buttons

    Twist or pull each E-stop button to the released position. Listen for the distinctive 'click' sound indicating proper mechanical reset.

    On older machines, E-stop buttons may require a quarter-turn clockwise after pulling out

  3. 3

    Verify TNC Safety Status

    Access MOD function and navigate to system information to check emergency stop status. The display should show 'E-STOP inactive' when properly reset.

    Use softkey sequence: MOD > System Info > Safety Status to verify E-stop circuit continuity

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety relay replacement required
  • ·TNC hardware input failure suspected
  • ·Machine manufacturer safety parameters need modification

Prevention

  • Perform weekly E-stop button function tests
  • Keep electrical cabinet clean and dry to prevent relay corrosion
  • Document any safety parameter changes for future reference

Common Mistakes

  • Assuming all E-stop buttons are reset when only checking the main panel button
  • Not verifying 24VDC supply voltage to safety relays
  • Attempting to bypass safety circuits instead of proper repair