Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-4130

Heidenhain 231-4130 - 4130 Contamination of Z1 track in encoder for axis

4130 Contamination of Z1 track in encoder for axis

Heidenhain error 231-4130: 4130 Contamination of Z1 track in encoder for axis. The position encoder or linear/rotary scale for the affected axis has reported a fault condition. The TNC control cannot obtain reliable position feedback from this axis until the encoder issue is resolved.

Root Cause Summary

HEIDENHAIN alarm 231-4130 indicates contamination on the Z1 track of the linear encoder for the specified axis, causing signal degradation and potential position feedback errors. This contamination interferes with the optical scanning unit's ability to read position data accurately from the scale.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Encoder Diagnostics

    Navigate to MOD function → Diagnosis → Encoder and check signal quality values for the affected axis. Look for degraded amplitude or DC offset values.

    Signal amplitude should typically be between 0.6-1.4V for optimal performance

  2. 2

    Inspect Scale Surface

    Visually examine the linear scale for visible oil film or coolant residue on the measuring track. Check the sealing lips of the scanning head for damage.

    Power down axis drives before physical inspection to prevent unexpected movement

  3. 3

    Clean Scale with Approved Solvent

    Use HEIDENHAIN cleaning fluid (part #336669-xx) or isopropyl alcohol with lint-free cloth to clean the scale surface. Clean in direction parallel to measuring track.

    Never use acetone or aggressive solvents that can damage the scale coating

  4. 4

    Verify Signal Recovery

    Return to encoder diagnostics and confirm signal quality values have returned to normal range. Clear alarm via PLC → Clear Error Messages.

    If contamination returns quickly, investigate coolant system leaks or inadequate sealing

DIY Feasiblehigh confidence

Call a technician if:

  • ·Signal quality remains poor after cleaning
  • ·Scanning head requires replacement
  • ·Scale mounting shows mechanical damage
  • ·Multiple encoder alarms occur simultaneously

Prevention

  • Implement regular scale cleaning schedule
  • Maintain proper coolant system sealing
  • Monitor chip evacuation effectiveness
  • Check way cover integrity monthly

Common Mistakes

  • Using wrong cleaning solvents
  • Excessive cleaning pressure
  • Ignoring sealing lip condition
  • Improper mounting torque

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.