axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
Heidenhain 231-4130 - 4130 Contamination of Z1 track in encoder for axis
HEIDENHAIN alarm 231-4130 indicates contamination on the Z1 track of the linear encoder for the specified axis, causing signal degradation and potential position feedback errors. This contamination interferes with the optical scanning unit's ability to read position data accurately from the scale.
Heidenhain 231-4130 - 4130 Contamination of Z1 track in encoder for axis
4130 Contamination of Z1 track in encoder for axis
Heidenhain error 231-4130: 4130 Contamination of Z1 track in encoder for axis. The position encoder or linear/rotary scale for the affected axis has reported a fault condition. The TNC control cannot obtain reliable position feedback from this axis until the encoder issue is resolved.
Root Cause Summary
HEIDENHAIN alarm 231-4130 indicates contamination on the Z1 track of the linear encoder for the specified axis, causing signal degradation and potential position feedback errors. This contamination interferes with the optical scanning unit's ability to read position data accurately from the scale.
Safety
Causes and Fixes
Access Encoder Diagnostics
Navigate to MOD function → Diagnosis → Encoder and check signal quality values for the affected axis. Look for degraded amplitude or DC offset values.
Signal amplitude should typically be between 0.6-1.4V for optimal performance
Inspect Scale Surface
Visually examine the linear scale for visible oil film or coolant residue on the measuring track. Check the sealing lips of the scanning head for damage.
Power down axis drives before physical inspection to prevent unexpected movement
Clean Scale with Approved Solvent
Use HEIDENHAIN cleaning fluid (part #336669-xx) or isopropyl alcohol with lint-free cloth to clean the scale surface. Clean in direction parallel to measuring track.
Never use acetone or aggressive solvents that can damage the scale coating
Verify Signal Recovery
Return to encoder diagnostics and confirm signal quality values have returned to normal range. Clear alarm via PLC → Clear Error Messages.
If contamination returns quickly, investigate coolant system leaks or inadequate sealing
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.