Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0507

HEIDENHAIN 230-0507 - Error during graphical visualization of a monitoring task

Error during graphical visualization of a monitoring task

An internal error occurred during graphical visualization of component or process monitoring values.

Root Cause Summary

The alarm is triggered when the TNC control's graphical subsystem cannot process or display monitoring data visualization due to configuration errors, resource limitations, or software conflicts. This is specifically related to the Process Monitoring or Adaptive Feed Control graphical interface components, not the monitoring function itself. The monitoring task may continue running in the background, but its visual representation fails.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Locate the monitoring configuration

    Navigate to TNC:\system\AFC\ for Adaptive Feed Control or TNC:\system\TPM\ for Tool Process Monitoring. Identify the active .CFG or monitoring configuration file being used.

    The active configuration filename is typically displayed in the monitoring task setup menu under MOD > Monitoring functions.

  2. 2

    Open configuration in text editor

    Use the TNC's built-in editor (Programming and Editing operating mode, select file type TXT/CFG) to open the configuration file. Look for sections defining graphical parameters like GRAPH_TYPE, DISPLAY_MODE, or CHART_CONFIG.

    Create a backup copy of the configuration file before making any changes.

  3. 3

    Validate graphical parameters

    Check that all graphical parameter values are within valid ranges per Heidenhain documentation. Common errors include invalid color codes, out-of-range axis scaling values, or missing closing brackets in parameter blocks.

    Compare with a working default configuration file from another machine or from the control's backup directory TNC:\system\backup\.

  4. 4

    Reset to default visualization

    Comment out or remove complex graphical parameters and use only basic visualization settings. Reload the monitoring task and verify if the alarm clears. Gradually re-enable graphical features to isolate the problematic parameter.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Software update required
  • ·Hardware display interface replacement needed
  • ·Persistent alarms after all troubleshooting steps

Prevention

  • Limit concurrent monitoring tasks to 4 maximum
  • Regularly clear monitoring task history logs
  • Keep TNC software updated to latest stable version

Common Mistakes

  • Enabling too many monitoring tasks simultaneously
  • Ignoring system memory warnings
  • Not resetting graphics subsystem after alarm occurrence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.