Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

140-001A

HEIDENHAIN 140-001A - Configuration object / not found

Configuration object / not found

A configuration object required for the control startup is missing. Without this object, the system cannot initialize properly.

Root Cause Summary

The control's configuration system has an internal reference to a named object (axis, spindle, PLC element, or I/O assignment) that does not exist in the system integration configuration files. This broken reference prevents proper initialization of the control system and must be corrected by either adding the missing object definition or removing the invalid reference.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Identify the missing object

    Record the exact object name from the alarm message placeholders '%1' and '%2'. Press the alarm softkey to view full details if truncated.

    Use MOD → Diagnose → Log File Viewer to see the complete alarm text if the display truncates long object names.

  2. 2

    Access system configuration directory

    Press MOD key, select 'System Files', navigate to TNC:\system\ directory. You need access authorization level for viewing system files.

    Changes to system configuration files require proper authorization and can render the machine inoperable if done incorrectly. Document original settings before making changes.

  3. 3

    Check axis key assignment file

    Open CfgAxisKeysAssignment.sys and search for the object name from the alarm. Verify that this name matches exactly (case-sensitive) with an object defined in the SIK file.

    Use the TNC editor's search function (FIND SOFTKEY) to quickly locate object references in large configuration files.

  4. 4

    Verify SIK object definition

    Open SYS.SIK or the machine-specific .SIK file (e.g., machineXXXXX.SIK). Search for the object definition section corresponding to the alarm (e.g., [AXIS], [SPINDLE]). Either add the missing object with proper configuration or correct the name to match the reference.

    Each object type has required parameters. For axes, minimum requirements include driveConfig, positionEncoder, and referenceSwitch assignments.

  5. 5

    Restart control and verify

    After correcting the configuration, perform a full control restart (power cycle recommended). Monitor the startup sequence for the alarm. Check MOD → Diagnose → Log Files for any remaining configuration warnings.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware replacement required
  • ·Software corruption beyond repair
  • ·Safety parameter configuration needed

Prevention

  • Regular configuration backups
  • Proper software update procedures
  • Document all parameter changes
  • Use UPS for stable power during updates

Common Mistakes

  • Restoring incompatible configuration backups
  • Modifying critical parameters without documentation
  • Interrupting software updates
  • Ignoring hardware status warnings