Heidenhain Controller
Parameter · Intermediate · 30-120 minutes
HEIDENHAIN 140-0021 - Data object renamed to key
This informational message occurs during normal TNC file management operations when the control prevents data loss by automatically renaming a data object to avoid overwriting an existing file with the same name. It is a protective mechanism, not a fault condition, and typically occurs during file transfers, backup/restore operations, or system synchronization activities.
HEIDENHAIN 140-0021 - Data object renamed to key
Data object renamed to key
The loaded configuration data comes from an older control version. A data object was automatically renamed according to update rules.
Root Cause Summary
This informational message occurs during normal TNC file management operations when the control prevents data loss by automatically renaming a data object to avoid overwriting an existing file with the same name. It is a protective mechanism, not a fault condition, and typically occurs during file transfers, backup/restore operations, or system synchronization activities.
Safety
Causes and Fixes
Access File Management
Press the PGM MGT (Program Management) key to open the file manager and navigate to the directory where the renamed file is located (typically TNC:\ or the working directory shown in the message).
Use the search function in PGM MGT by pressing the 'Find' soft key to quickly locate both the original and renamed files.
Identify Duplicate Files
Look for both filenames mentioned in the message ('%1' and '%2'). Compare file sizes and timestamps to determine which file is the intended version.
Select each file and press 'File Info' soft key to view detailed creation and modification timestamps.
Resolve Naming Conflict
Delete the unwanted duplicate file, or rename one of the files to a unique descriptive name. Select the file, press the 'Rename' soft key, and enter the desired name following TNC naming conventions (no special characters, max 16 characters).
Establish a naming convention with version suffixes (e.g., PART_V1.H, PART_V2.H) to prevent future conflicts.
Verify File Integrity
Open the file in editing mode to verify its content is correct and complete. For NC programs, check the program header and final M30/M02. For tables, verify all data rows are present.
For critical programs, run a test graphics simulation before machining to ensure the correct program version is active.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.