Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

140-0026

HEIDENHAIN 140-0026 - Attribute inserted in data object Attribute

Attribute inserted in data object Attribute

The loaded configuration data comes from an older control version. Missing attributes were automatically inserted into an incomplete data object by update rules.

Root Cause Summary

This alarm indicates that the TNC control has automatically added a missing attribute to a data object to maintain compatibility with the current software version. This commonly occurs during software updates, file imports from older controls, or when the control detects incomplete data structures that need to be updated to current format standards.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Identify Updated Data Object

    Read the alarm parameters '%1' (object type), '%2' (object name), and '%3' (attribute name) from the error log. Press MOD > Service > Error Messages to view complete alarm details with all parameters.

    Common objects affected include tool.t, preset.pr, kinematics.h, and tncopt.sys files during major version updates.

  2. 2

    Verify Software Version Change

    Check MOD > System Settings > Software Info to confirm current NC software version. Compare with previous version documented in machine records to identify if upgrade occurred.

    Updates from iTNC 530.xxx to TNC 640.xxx or within major build numbers (e.g., 340.xxx to 640.xxx) frequently trigger data structure updates.

  3. 3

    Review Inserted Attribute

    Open the affected data object (e.g., tool table via MOD > Tool Table or preset table via MOD > Datum Table) and verify the new attribute appears with appropriate default values.

    New attributes typically receive safe default values (0, empty string, or OFF) - verify these defaults are appropriate for your machining operations.

  4. 4

    Clear Alarm and Document

    Acknowledge the alarm using the CE (Clear Error) key. Document the software version change and affected data objects in machine maintenance log for future reference.

    This alarm is informational - the control has already corrected the data structure. No further action is typically required unless default values need adjustment.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter backup corruption
  • ·Repeated alarm after parameter updates
  • ·Axis positioning errors after attribute insertion

Prevention

  • Always backup machine parameters before software updates
  • Document parameter file versions during system upgrades
  • Regularly save updated parameter files after TNC software updates

Common Mistakes

  • Ignoring the alarm assuming it's harmless
  • Not backing up original parameters before updates
  • Failing to verify machine operation after attribute insertion

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?