HEIDENHAIN 130-0192 - ASSERTION: Consistency condition not fulfilled
This assertion alarm indicates the TNC control detected an internal inconsistency that violates fundamental operating assumptions, typically caused by memory corruption, software bugs, or hardware faults affecting data integrity. The control's self-monitoring system has halted operation to prevent machine damage or unpredictable behavior resulting from invalid internal states.
HEIDENHAIN 130-0192 - ASSERTION: Consistency condition not fulfilled
ASSERTION: Consistency condition not fulfilled
This TNC7/TNC 640 error (130-0192) relates to 'ASSERTION: Consistency condition not fulfilled'. System error
Root Cause Summary
This assertion alarm indicates the TNC control detected an internal inconsistency that violates fundamental operating assumptions, typically caused by memory corruption, software bugs, or hardware faults affecting data integrity. The control's self-monitoring system has halted operation to prevent machine damage or unpredictable behavior resulting from invalid internal states.
Safety
Causes and Fixes
Access System Log Files
Press MOD key, navigate to System > LOG FILES, and examine the *.log files for detailed assertion information. Note the timestamp, module name, and assertion condition that failed.
The log file typically contains the exact source code location (file and line number) of the failed assertion, which is critical information for Heidenhain support analysis.
Verify Software Version Integrity
In MOD mode, select System Information and verify the software version matches expected installation. Check for partial or incomplete software updates indicated by mismatched build numbers.
Do not attempt software operations while machine axes are enabled or workpieces are mounted.
Backup Current Configuration
Using TNCbackup or MOD > Backup > Create Backup, save current machine parameters and PLC program to external media before any software reinstallation attempts.
Perform Clean Software Installation
Boot control with installation media (USB/CF card), select 'New Installation' option, and reload the complete TNC software package. Restore machine parameters after successful installation.
Use the latest service pack version available for your control model, as many assertion-related bugs are fixed in newer releases.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.