HEIDENHAIN 130-0192 - ASSERTION: Consistency condition not fulfilled

ASSERTION: Consistency condition not fulfilled

This TNC7/TNC 640 error (130-0192) relates to 'ASSERTION: Consistency condition not fulfilled'. System error

Root Cause Summary

This assertion alarm indicates the TNC control detected an internal inconsistency that violates fundamental operating assumptions, typically caused by memory corruption, software bugs, or hardware faults affecting data integrity. The control's self-monitoring system has halted operation to prevent machine damage or unpredictable behavior resulting from invalid internal states.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access System Log Files

    Press MOD key, navigate to System > LOG FILES, and examine the *.log files for detailed assertion information. Note the timestamp, module name, and assertion condition that failed.

    The log file typically contains the exact source code location (file and line number) of the failed assertion, which is critical information for Heidenhain support analysis.

  2. 2

    Verify Software Version Integrity

    In MOD mode, select System Information and verify the software version matches expected installation. Check for partial or incomplete software updates indicated by mismatched build numbers.

    Do not attempt software operations while machine axes are enabled or workpieces are mounted.

  3. 3

    Backup Current Configuration

    Using TNCbackup or MOD > Backup > Create Backup, save current machine parameters and PLC program to external media before any software reinstallation attempts.

  4. 4

    Perform Clean Software Installation

    Boot control with installation media (USB/CF card), select 'New Installation' option, and reload the complete TNC software package. Restore machine parameters after successful installation.

    Use the latest service pack version available for your control model, as many assertion-related bugs are fixed in newer releases.

Service Recommendedmedium confidence

Call a technician if:

  • ·Memory test failures detected
  • ·Multiple servo drives showing communication errors
  • ·Assertion error persists after parameter reset
  • ·Hardware temperature warnings present

Prevention

  • Maintain stable power supply conditions
  • Keep control cabinet temperatures within specification
  • Perform regular encoder cable inspections
  • Monitor system performance metrics regularly
  • Maintain proper EMI shielding and grounding

Common Mistakes

  • Ignoring intermittent encoder signal issues
  • Modifying servo parameters without understanding dependencies
  • Operating with high system CPU loads
  • Neglecting cooling system maintenance
  • Mixing incompatible software versions

Seeing Multiple Alarms?