HEIDENHAIN 130-0199 - OEM error without additional information
This alarm is exclusively generated by the machine tool builder's custom programming and indicates an error condition specific to their machine design. The 'without additional information' suffix means the OEM failed to provide descriptive alarm text during their software configuration, making diagnosis dependent on OEM-specific documentation or direct communication with the machine manufacturer.
HEIDENHAIN 130-0199 - OEM error without additional information
OEM error without additional information
An OEM-specific error was raised but no explanatory text is available. The error-text file is either absent or incomplete.
Root Cause Summary
This alarm is exclusively generated by the machine tool builder's custom programming and indicates an error condition specific to their machine design. The 'without additional information' suffix means the OEM failed to provide descriptive alarm text during their software configuration, making diagnosis dependent on OEM-specific documentation or direct communication with the machine manufacturer.
Safety
Causes and Fixes
Access PLC Programming Mode
Press MOD function, select 'PLC Programming' or 'Service' menu (password may be required). Navigate to the PLC marker display to view current PLC states.
On iTNC 530 and newer, use the integrated PLC monitor (DIAG->PLC) to filter markers by recent changes to quickly identify which marker triggered the alarm.
Modifying PLC code without proper authorization may void machine warranty and create safety hazards.
Identify Alarm Trigger Marker
Search PLC program for alarm number 130 or 0199. Look for NC-PLC marker commands like 'M_ALARM' or error flag assignments (typically M4xxx or M5xxx range markers) that reference this alarm code.
OEM alarm triggers often use structured marker naming like M4199 for alarm 199. Check markers in the 4000-5000 range first.
Trace PLC Condition Logic
Once the alarm-triggering marker is identified, trace backward through the PLC logic to find the input condition, timer, or sequence that sets this marker. Document the sensor inputs or NC states involved.
Use the PLC cross-reference function to find all locations where the alarm marker is written or modified.
Resolve Underlying Machine Condition
Based on the PLC logic analysis, check the physical machine condition (limit switches, pressure sensors, temperature monitors, etc.) or NC state that is causing the error flag to be set.
Common OEM triggers include hydraulic pressure low, chip conveyor faults, coolant level, or tool changer position errors.
Call a technician if:
Prevention