HEIDENHAIN 130-0195 -
This alarm is triggered when the TNC's real-time operating system cannot allocate additional task scheduler resources for time-critical PLC jobs. The root cause is typically an overloaded or poorly optimized PLC program that exceeds the control's capacity for concurrent time-dependent operations, or system-level corruption affecting the task management kernel.
HEIDENHAIN 130-0195 -
This TNC7/TNC 640 error (130-0195) relates to ''. No further time job could be started.
Root Cause Summary
This alarm is triggered when the TNC's real-time operating system cannot allocate additional task scheduler resources for time-critical PLC jobs. The root cause is typically an overloaded or poorly optimized PLC program that exceeds the control's capacity for concurrent time-dependent operations, or system-level corruption affecting the task management kernel.
Safety
Causes and Fixes
Access PLC Task Diagnostics
Press MOD key → select 'System' → 'PLC' → 'Diagnostics' or 'Task Overview'. Review active cyclic tasks and their execution times. Look for tasks with unusually high cycle times or excessive quantity of timed OBs.
On iTNC 530/TNC 620/640, you can also access detailed PLC load information via MOD → Settings → System Configuration → PLC Runtime.
Review PLC Program Structure
Contact machine manufacturer for PLC source code review. Identify cyclic OBs (organization blocks) with time-critical triggering, particularly OB10-OB38 which are time-interrupt driven. Check if multiple fast-cycle OBs are running simultaneously.
Do not modify PLC program without machine manufacturer authorization and complete system backup, as this can affect safety functions.
Optimize or Consolidate PLC Tasks
Work with machine builder to consolidate redundant time jobs, increase cycle times for non-critical tasks, or move operations to the main PLC cycle (OB1) instead of using separate timed interrupts.
Moving routine checks from 10ms interrupt OBs to 50ms or 100ms cycles can significantly reduce scheduler load without affecting machine performance.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.