axismd.ai
Heidenhain Controller
System · Intermediate · 30-120 minutes
HEIDENHAIN 130-0136 -
This alarm specifically indicates that essential system objects required for the TNC control's operation are missing or inaccessible during the boot sequence. The most common root cause is an incomplete or corrupted NC software installation, though hardware failures affecting the storage medium can also prevent proper object loading. The control's self-diagnostic routine detects this incomplete system state and prevents startup to avoid unpredictable behavior.
HEIDENHAIN 130-0136 -
The control cannot start because required objects are absent. This usually points to corrupted or incomplete system data.
Root Cause Summary
This alarm specifically indicates that essential system objects required for the TNC control's operation are missing or inaccessible during the boot sequence. The most common root cause is an incomplete or corrupted NC software installation, though hardware failures affecting the storage medium can also prevent proper object loading. The control's self-diagnostic routine detects this incomplete system state and prevents startup to avoid unpredictable behavior.
Safety
Causes and Fixes
Access Service Mode
Power off the control completely. Power on while holding the MOD key to enter Service Mode. This bypasses normal startup and allows access to recovery functions.
If MOD key access fails, the system partition itself may be damaged and require Heidenhain service intervention.
Check System Log Files
In Service Mode, navigate to System > Log Files. Review the startup log (syslog.txt) and look for specific object names or initialization failures that caused the 130-0136 alarm.
Take photos or notes of specific missing object names - this information is critical for determining if a full reinstall is needed.
Attempt System Restore
From Service Mode menu, select 'Restore System' if a recovery partition exists. Choose the most recent stable system restore point before the failed update or installation.
System restore will revert to the previous software version and may lose recent configuration changes not backed up.
Reinstall NC Software
If restore fails, perform complete NC software reinstallation using Heidenhain installation media (USB or DVD). Boot from installation media and select 'Complete Installation' option. Follow prompts to reinstall all system objects.
Ensure you have machine parameters and PLC program backups before reinstalling. Machine-specific data must be reloaded after fresh installation.
Restore Machine Configuration
After successful reinstallation, restore machine parameters from TNC:\system\backup or external backup media. Reload PLC program and cycle definitions specific to your machine.
Use MOD > File System to verify all required files in TNC:\system\objects directory are present with valid timestamps after installation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.