HAAS Alarm 45 - Machine Lubrication System Fault
Haas Alarm 45 fires when the automatic lubrication system pressure switch detects insufficient pressure to deliver oil to critical machine components. The NGC control monitors lubrication pressure through a dedicated input and triggers this alarm when pressure drops below the minimum threshold required for proper spindle, ballscrew, and way lubrication.
HAAS Alarm 45 - Machine Lubrication System Fault
Lubrication System Pressure Low
The MOCON board has detected insufficient pressure from the automatic lubrication system that services the machine ways and ballscrews. This alarm is triggered when the pressure switch input on IOCON does not register adequate pressure within the programmed time window after the lube pump activates. The machine will not allow cycle start until proper lubrication system pressure is restored and verified.
Root Cause Summary
Haas Alarm 45 fires when the automatic lubrication system pressure switch detects insufficient pressure to deliver oil to critical machine components. The NGC control monitors lubrication pressure through a dedicated input and triggers this alarm when pressure drops below the minimum threshold required for proper spindle, ballscrew, and way lubrication.
Safety
Causes and Fixes
Check Oil Level
Open electrical cabinet and visually inspect the clear oil reservoir tank mounted near the lubrication pump. Oil level should be visible above minimum mark.
Ensure main power is locked out before opening electrical cabinet
Refill Reservoir
If empty, refill with Haas-approved Way Oil (Mobil Vactra #2 or equivalent ISO 68 slideway oil). Fill to maximum line on reservoir.
Use a funnel to prevent spillage and contamination
Prime System
After refilling, manually cycle the lubrication pump using the LUBE button on the control panel or through CURRENT COMMANDS > COOLANT/LUBE menu to prime the system.
May take several cycles to fully prime if system was completely empty
Reset Alarm
Press RESET button and verify alarm clears. Monitor pressure gauge if equipped to confirm proper operating pressure (typically 15-25 PSI).
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?