FANUC Controller
Servo/Axis · Intermediate · 30-90 minutes
Fanuc SV0434 - Servo alarm: n axis psm cooling fan stop
The FANUC SV0434 alarm typically results from a failure in the servo amplifier's internal DC control voltage circuit, often due to degraded capacitors or voltage regulator issues. The most likely fix involves inspecting and replacing the faulty servo amplifier or addressing control power supply issues. In some cases, external wiring or power supply module problems may also contribute to this alarm.
Fanuc SV0434 - Servo alarm: n axis psm cooling fan stop
SERVO ALARM: n AXIS PSM COOLING FAN STOP
The servo amplifier has detected that the internal DC control voltage (typically +24VDC) used to operate the inverter control circuits has fallen below the acceptable threshold. This low voltage condition prevents proper servo amplifier operation and triggers a protective shutdown to prevent erratic axis motion or component damage. The alarm indicates the specific axis amplifier experiencing the control voltage problem.
Root Cause Summary
The FANUC SV0434 alarm typically results from a failure in the servo amplifier's internal DC control voltage circuit, often due to degraded capacitors or voltage regulator issues. The most likely fix involves inspecting and replacing the faulty servo amplifier or addressing control power supply issues. In some cases, external wiring or power supply module problems may also contribute to this alarm.
Safety
Causes and Fixes
Check Control Voltage Readings
Navigate to the DIAGNOSIS screen (System > Servo > Monitor) and record the control voltage for the faulted axis. It should be 24VDC ±10%. A significantly lower value indicates internal circuit failure.
Compare the voltage reading with other axes to identify if the issue is isolated to this amplifier.
Ensure the machine is powered down and locked out before proceeding to physical inspection.
Inspect Amplifier Control Board
Power down the machine, apply LOTO, and remove the servo amplifier cover. Visually inspect the control board for bulging capacitors, burn marks, or cracked traces that could indicate a failure in the voltage regulation circuit.
Use a magnifying glass to spot micro-cracks or subtle discoloration on the board.
Wait at least 5 minutes after power-down and verify no residual voltage with a multimeter before touching components.
Test with Replacement Amplifier
If damage is suspected or voltage is out of spec, swap the amplifier with a known-good unit of the same model. Transfer necessary parameters and test the axis. If the alarm clears, the original amplifier is defective and needs repair or replacement.
Document all parameter settings before swapping to ensure proper configuration of the replacement unit.
Incorrect parameter settings during swap can cause unexpected axis motion. Double-check settings before power-up.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.