FANUC Alarm SP11 - DC Link High Voltage
The FANUC Alarm SP11 - DC Link High Voltage is typically caused by excessive regenerative energy during spindle deceleration or an AC input voltage that exceeds the drive's rated capacity. The most likely fix involves adjusting spindle deceleration parameters or verifying and correcting the input voltage. In some cases, a failed regenerative discharge resistor may also be the culprit.
FANUC Alarm SP11 - DC Link High Voltage
DC Link High Voltage
The DC bus voltage inside the Fanuc Alpha spindle drive has risen above the maximum allowable level. DC bus overvoltage occurs when regenerative energy from a decelerating spindle motor cannot be dissipated fast enough, or when the AC input voltage is higher than the drive rating.
Root Cause Summary
The FANUC Alarm SP11 - DC Link High Voltage is typically caused by excessive regenerative energy during spindle deceleration or an AC input voltage that exceeds the drive's rated capacity. The most likely fix involves adjusting spindle deceleration parameters or verifying and correcting the input voltage. In some cases, a failed regenerative discharge resistor may also be the culprit.
Causes and Fixes
Measure Input Voltage
Use a digital multimeter to measure the AC voltage at the input terminals of the Power Supply Module (PSM) or spindle drive. Compare the reading to the rated voltage on the drive's nameplate.
Measure during peak load times to catch any voltage surges that might not be present during idle periods.
Ensure the machine is powered off and follow lockout-tagout procedures before accessing terminals.
Consult Facility Electrician
If the measured voltage exceeds the rated value (e.g., >240V for a 200-240V drive), notify the facility electrician to investigate and adjust the incoming power supply or install a step-down transformer.
Document the voltage readings with timestamps to provide evidence for the electrician.
Do not attempt to modify facility power lines yourself; this requires a licensed professional.
Install Line Reactor if Needed
If voltage spikes are detected (using a power quality meter), install a line reactor or surge suppressor on the AC input to stabilize the voltage and prevent future overvoltage alarms.
Choose a line reactor rated for the drive's input current to ensure proper protection.
Improper installation of a line reactor can cause additional electrical issues; verify compatibility with the drive.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.