PS100

Fanuc PS100 - Parameter Write Enable

Parameter Write Enable

Fanuc PS100 indicates that the parameter write enable switch (PWE) has been turned on. This is not an error alarm — it is a warning that CNC parameters can now be modified. Machine operation may be restricted while PWE is active depending on the control configuration.

Root Cause Summary

The Fanuc Alarm PS100 indicates the parameter write enable switch is ON, which allows parameter modifications. This is typically intentional for maintenance/setup but should be disabled after use to prevent accidental changes. CRITICAL: Never disable PWE if parameter editing is actively in progress.

Safety

  • Lock parameters when done editing

Causes and Fixes

  1. 1

    Check PWE Switch Status

    Navigate to the system parameter screen on the CNC control panel and check if the Parameter Write Enable (PWE) switch or bit is set to 1 (ON).

    Take a photo of the screen before making changes to document the original state.

    Do not modify other parameters while checking to avoid unintended changes.

  2. 2

    Disable PWE Switch

    Set the PWE bit to 0 (OFF) using the appropriate key or menu option on the control panel to disable parameter writing.

    Double-check the setting after changing to ensure it has been applied.

    Ensure no parameter changes are needed before disabling.

  3. 3

    Cycle Power to Confirm

    Power cycle the CNC machine to ensure the alarm clears and the PWE setting remains OFF.

    Monitor for recurring alarms after power cycle to rule out deeper issues.

    Follow proper shutdown procedures to avoid data loss.

DIY Feasiblehigh confidence

Call a technician if:

  • ·If the alarm persists after disabling PWE and power cycling.
  • ·If a hardware fault is suspected with the control panel or switch.

Prevention

  • Always disable PWE immediately after completing parameter edits
  • Implement a checklist for operators to verify PWE status before and after shifts
  • Train staff on proper parameter handling and locking procedures
  • Use lockout/tagout procedures when parameter editing is in progress
  • Maintain a parameter change log with timestamps and personnel

Common Mistakes

  • Forgetting to disable PWE after parameter changes, leading to accidental modifications.
  • Ignoring the alarm assuming it’s benign, which risks unintended parameter edits.

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.