Fanuc Alarm 319 - END POINT COMMAND ILLEGAL IN DRILLING CYCLE
Fanuc Alarm 319 occurs when a G74 (peck drilling cycle for facing) or G75 (outer diameter/inner diameter grooving cycle) is programmed with a zero travel distance (depth per cut) but specifies a non-zero endpoint value in U or W. This creates a logical conflict where the cycle has an endpoint to reach but no incremental movement per cycle to get there.
Fanuc Alarm 319 - END POINT COMMAND ILLEGAL IN DRILLING CYCLE
SYSTEM ALARM 319
Fanuc alarm 319: SYSTEM ALARM 319. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 319 occurs when a G74 (peck drilling cycle for facing) or G75 (outer diameter/inner diameter grooving cycle) is programmed with a zero travel distance (depth per cut) but specifies a non-zero endpoint value in U or W. This creates a logical conflict where the cycle has an endpoint to reach but no incremental movement per cycle to get there.
Causes and Fixes
Review the G74 or G75 block in the active program. For G74, verify format G74 R(retract) G74 X(or Z) I(depth increment) K(depth increment) U(endpoint) W(endpoint). For G75, verify similar syntax with appropriate axis assignments per your Fanuc lathe configuration.
Check if the first I or K value (depth per cut) is programmed as zero or omitted while U or W has a non-zero value. Example of incorrect code: G74 R1.0; G74 Z-50. I0 K10. U-20.; where I0 creates the alarm.
Correct the program by specifying a non-zero incremental depth value (I or K) that matches the axis of motion, or remove the U/W endpoint command if no endpoint offset is intended. Example correction: G74 Z-50. I5. K10. U-20.; with I5 providing proper peck depth.
Execute a program check (PROGRAM > EDIT mode, then press RESET and search for G74/G75 cycles) to verify all drilling/grooving cycles have proper incremental and endpoint values before running in AUTO mode.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.