FANUC codes
FANUCProgram/G-codeIntermediate5-30 minutes

295

Fanuc 295 - Figure copy not ready

FIGURE COPY NOT READY

Fanuc PS program alarm 295: FIGURE COPY NOT READY. This alarm is triggered by an illegal or incorrectly formatted command in the part program, or a programming condition that the Fanuc control cannot execute.

Root Cause Summary

Alarm 295 occurs when the control attempts to execute a figure copy command (typically G73.1 or similar pattern repeat function) but the required figure definition or copy conditions have not been properly established. This is most commonly caused by missing figure registration, attempting to copy before defining the source figure, or calling a figure number that doesn't exist in memory.

Safety

  • Verify corrected program or parameters before resuming machining

Causes and Fixes

  1. 1

    Review the part program and locate the G73.1 (or figure copy) command that triggered the alarm.

  2. 2

    Trace backwards in the program to verify a figure registration command (G73.2 or G72.1 depending on system) exists with matching figure number before the copy command.

  3. 3

    Verify the figure definition block includes proper start point, geometry definition, and end registration command without any gaps or interruptions.

  4. 4

    Ensure the figure number called in the copy command exactly matches the registered figure number (check for typos or incorrect figure IDs).

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.