Fanuc Alarm 233 - DEVICE BUSY
Fanuc alarm 233 DEVICE BUSY occurs when multiple processes or programs attempt to access the same RS-232-C serial communication port simultaneously. This is typically caused by conflicting I/O operations such as a running macro reading/writing to the port while an operator attempts manual communication, or dual PMC ladder logic attempting concurrent serial access.
Fanuc Alarm 233 - DEVICE BUSY
SYSTEM ALARM 233
Fanuc alarm 233: SYSTEM ALARM 233. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc alarm 233 DEVICE BUSY occurs when multiple processes or programs attempt to access the same RS-232-C serial communication port simultaneously. This is typically caused by conflicting I/O operations such as a running macro reading/writing to the port while an operator attempts manual communication, or dual PMC ladder logic attempting concurrent serial access.
Causes and Fixes
Press SYSTEM key, navigate to PROGRAM > check if any macro programs are currently executing in background. Look for programs using DPRNT, POPEN, PCLOS, or file I/O operations.
Check parameter 20 (I/O channel selection for RS-232-C). Verify parameters 100-109 (RS-232-C port configuration) to identify which port is assigned. Note parameter 101 bit 0 (STX) and bit 1 (output device selection).
Navigate to SYSTEM > PARAM > search for parameter 3107 (DNC operation mode). If set to 1 or 2, DNC operations may conflict with manual RS-232-C access attempts.
Reset the alarm, wait for current macro serial operation to complete (check program execution status), then retry the desired RS-232-C communication. Consider adding M-code wait logic in macro programs using serial I/O.
Do not interrupt macro execution forcibly during file write operations as this may corrupt data transfer
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.