Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

8045

Siemens 840D 8045 - Option for selected cycle settings not set

Option for selected cycle settings not set

Siemens SINUMERIK alarm 8045: Option for selected cycle settings not set. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

Alarm 8045 indicates that the 840D cycle time synchronization option is not activated on an 810D Powerline control, preventing the use of 840D-compatible IPO cycle grid settings. The NCK is configured to use only standard 810D controller parameters, which are incompatible with 840D servo cycle timing requirements.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access HMI Menu: Diagnosis > Parameters > Machine Data. Navigate to MD 30110 (NCK_CYCLE_TIME) and verify it matches the required 840D cycle time (e.g., 0.001s for 1 ms, 0.004s for 4 ms).

  2. 2

    Check MD 30115 (IPO_BASE_TIME) value. For 840D option activation, this must be set to a value corresponding to the 840D standard grid. If MD 30115 shows 0 or default 810D value, the option is not enabled.

    Changing cycle time parameters requires control system restart and safety validation.

  3. 3

    Verify license file in NCK: Use SINUMERIK Operate HMI > System > Service > License. Confirm that '840D_Option' or equivalent license key is present and valid in the control's license database.

  4. 4

    If license is missing, contact Siemens support with the control's serial number (displayed in HMI > System > Information) to obtain and install the 840D Powerline upgrade license package.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.