Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

75600

Siemens 75600 - RESU: wrong MD configuration. Error code

RESU: wrong MD configuration. Error code

The following errors were detected in the machine data of the retrace support function when ramping up: Error code = 4: Machine date $MC_MM_NUM_CC_BLOCK_ELEMENTS or $MC_MM_NUM_CC_BLOCK_USER_MEM must be increased. Error code = 5: Insufficient heap memory for compile cycles available. Adjust machine data $MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM and $MC_MM_NUM_CC_HEAP_MEM. Error code = 6: The machine data $MN_ASUP_START_MASK and $MN_ASUP_START_PRIO_LEVEL are not set correctly. Error code = 11: Machine data $MC_AXCONF_GEOAX_NAME_TAB[n], $MN_INTERMEDIATE_POINT_NAME_TAB[n] and $MN_IPO_PARAM_NAME_TAB[n] are not set correctly for RESU: Error code = 13: With bit 2 = 0 of MD $MC_RESU_SPECIAL_FEATURE_MASK it was specified that the retraction program cc_resu.mpf is to be stored in the DRAM parts program memory. However, no DRAM parts program memory was requested via MD $MN_MM_DRAM_FILE_MEM_SIZE. Remedy: Either set MD $MN_MM_DRAM_FILE_MEM_SIZE to a value inequal to zero or set bit 2 of MD $MC_RESU_SPECIAL_FEATURE_MASK equal to one Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The following errors were detected in the machine data of the retrace support function when ramping up: Error code = 4 : Machine date $MC_MM_NUM_CC_BLOCK_ELEMENTS or $MC_MM_NUM_CC_BLOCK_USER_MEM must be increased.
  • Error code = 5 : Insufficient heap memory for compile cycles available.
  • Adjust machine data $MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM and $MC_MM_NUM_CC_HEAP_MEM.

Troubleshooting Steps

  1. 1Correct machine data.
  2. 2Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.