Siemens 70001 - Channel Yf is larger than distance C1-Cy
Alarm 70001 indicates that during JOG mode operation, the Yf axis position has exceeded the maximum permissible traverse distance defined by the C1-Cy parameter span. This violation occurs when the JOG command pushes the axis beyond its configured mechanical or software limits, typically due to incorrect limit configuration or calibration drift.
Siemens 70001 - Channel Yf is larger than distance C1-Cy
Channel Yf is larger than distance C1-Cy
In JOG mode, the Yf axis is traversed. The value of the Yf axis is larger than the distance C1-Cy Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
Alarm 70001 indicates that during JOG mode operation, the Yf axis position has exceeded the maximum permissible traverse distance defined by the C1-Cy parameter span. This violation occurs when the JOG command pushes the axis beyond its configured mechanical or software limits, typically due to incorrect limit configuration or calibration drift.
Safety
Causes and Fixes
Access Diagnostics menu: Siemens HMI > Diagnosis > Axis Data > select Yf axis. Verify current position against displayed limit values (C1 and Cy). Note the actual traverse range being attempted.
Do not jog beyond current position limits during this check.
In NCK parameters, navigate to MD32100 (C1 lower limit) and MD32110 (Cy upper limit) for the Yf axis. Compare configured values against mechanical drawing specifications and encoder calibration documentation. Calculate C1-Cy span and verify it matches machine capability.
If limits are incorrect, update MD32100 and MD32110 with correct values. Save parameters using 'Store to NVRAM' function in machine data editor. Perform warm restart (NC RESET) to activate changes.
Verify new parameters with machine builder before restart to prevent mechanical damage.
After restart, perform slow JOG movements in both directions near limits to confirm alarm no longer triggers. Monitor position display in real-time diagnostics.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.