Siemens 840D 6580 - NC memory full
Alarm 6580 indicates the NCK (Numeric Control Kernel) file system on the NC card has exceeded its storage capacity, preventing new part programs, macro files, or system data from being loaded into memory. This occurs when accumulated files consume all available flash or RAM storage allocated to the NC partition, blocking program execution and data transfers.
Siemens 840D 6580 - NC memory full
NC memory full
Siemens SINUMERIK alarm 6580: NC memory full. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6580 indicates the NCK (Numeric Control Kernel) file system on the NC card has exceeded its storage capacity, preventing new part programs, macro files, or system data from being loaded into memory. This occurs when accumulated files consume all available flash or RAM storage allocated to the NC partition, blocking program execution and data transfers.
Safety
Causes and Fixes
Access the NCK file system via HMI menu path: Diagnostics > File System or via SINUMERIK Operate interface under 'Program Management'. Navigate to the NC memory directory (typically //NC/prog or //NC/subroutines).
Identify and delete obsolete or test part programs using the file manager. Prioritize removal of large .mpf files (main programs) and .spf files (subprograms) that are no longer in production use.
Ensure deleted programs are backed up to external storage (USB, network drive) before permanent deletion to prevent loss of production data.
Verify available free space after deletion by checking the NCK partition status in Diagnostics > System Information > Storage or via MD parameter query for MD 18000 (memory configuration status).
If storage remains critically low after cleanup, implement a file rotation policy: archive completed job programs to external media and store only active production programs in NCK memory.