axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 840D 6570 - NC memory full
Alarm 6570 indicates the NCK DRAM file system has exhausted available memory, preventing new NC program blocks, system files, or temporary data from being written. This typically occurs when accumulated temporary files, diagnostic buffers, or excessive part program storage consume all available NC card memory without proper cleanup mechanisms.
Siemens 840D 6570 - NC memory full
NC memory full
Siemens SINUMERIK alarm 6570: NC memory full. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6570 indicates the NCK DRAM file system has exhausted available memory, preventing new NC program blocks, system files, or temporary data from being written. This typically occurs when accumulated temporary files, diagnostic buffers, or excessive part program storage consume all available NC card memory without proper cleanup mechanisms.
Safety
Causes and Fixes
Enter Diagnostics menu (Machine > Diagnostics > Alarms) and check NCK memory utilization via Service > System Information > Memory Statistics to quantify free DRAM percentage.
Navigate to Parameters > MD 30310 (max temporary files) and MD 32000 (trace buffer). Reduce MD 32000 from default 10MB to 2-4MB if diagnostics not actively required. Verify MD 20100 alarm buffer depth is ≤500 entries.
Reducing trace buffer may limit post-mortem diagnostics; document baseline values before adjustment.
Perform NCK DRAM reset via HMI: Machine > Maintenance > Clear Temporary Files, or issue FANUC-equivalent G-code command to purge .TMP directory. Then cycle power and retest program load.
If issue persists, check SD 55000 (NCK memory partition size). Verify allocation reflects actual hardware (e.g., SD 55000 = 64MB for 840D with 128MB DRAM). Consult machine builder OEM documentation for correct partition ratio.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.