Siemens 840D 6582 - NC machine OEM memory full
Alarm 6582 indicates the DRAM file system allocated to the machine OEM (Original Equipment Manufacturer) area has exhausted available storage capacity, preventing new part program or data writes. This typically occurs when OEM-specific functions, custom macros, or diagnostic data accumulate beyond the configured memory partition defined by MD 20090 (OEM memory size).
Siemens 840D 6582 - NC machine OEM memory full
NC machine OEM memory full
Siemens SINUMERIK alarm 6582: NC machine OEM memory full. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6582 indicates the DRAM file system allocated to the machine OEM (Original Equipment Manufacturer) area has exhausted available storage capacity, preventing new part program or data writes. This typically occurs when OEM-specific functions, custom macros, or diagnostic data accumulate beyond the configured memory partition defined by MD 20090 (OEM memory size).
Safety
Causes and Fixes
Access Siemens HMI or SINUMERIK Operate interface and navigate to Maintenance → Memory Management → OEM Memory to view current utilization percentage.
Back up OEM data via Automation License Manager (ALM) or direct FLOPPY/USB export, then delete obsolete macro versions, debug routines, or unused cycle definitions from NCK → Machine → OEM Data → Delete.
Ensure backup is validated before deletion to prevent loss of critical OEM functions.
If necessary, increase MD 20090 (OEM memory size) in step 7 parameters, then perform warm restart (Ctrl+Shift+F11) to reallocate the expanded partition.
Verify alarm clears by attempting to load a test part program; if alarm persists, check MD 20091 (OEM memory reserved) to ensure sufficient headroom (typically 10-15% of allocated size).
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.