Siemens 840D 6510 - Too many part programs in the NC memory
Alarm 6510 triggers when the NC file system reaches its maximum inode capacity, preventing creation of new part programs, drive data files, or system files in NCK memory. This occurs across all file types managed by the SINUMERIK file system, not just user part programs, and typically manifests during startup or program loading operations.
Siemens 840D 6510 - Too many part programs in the NC memory
Too many part programs in the NC memory
Siemens SINUMERIK alarm 6510: Too many part programs in the NC memory. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 6510 triggers when the NC file system reaches its maximum inode capacity, preventing creation of new part programs, drive data files, or system files in NCK memory. This occurs across all file types managed by the SINUMERIK file system, not just user part programs, and typically manifests during startup or program loading operations.
Safety
Causes and Fixes
Access the NCK file system via HMI menu: Diagnostics > File Management > NC Programs or via Siemens OPC/DNC interface. Count total .mpf, .spf, .h, and .src files present.
Do not attempt deletion during active CNC cycle; stop all program execution first.
Identify and archive obsolete part programs to external storage. Prioritize deletion of backup files (.bak), old revisions, and unused .h header files. Use HMI delete function or FTP to remove files from /nck directory.
Verify file backups exist before deletion; SINUMERIK does not have undelete capability.
Perform warm restart (NCK reset without power-down) via HMI: Utilities > System > Warm Start or press NC RESET button. Monitor alarm log to confirm 6510 clears.
Establish file management procedure: Monitor NCK file system usage via Diagnostics menu monthly. Set threshold alert when file count exceeds 80% of maximum inode capacity to prevent future occurrences.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?