Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-45 minutes

61406

Siemens 840D 61406 - Channel block: check DL number in _DLNUM

Channel block: check DL number in _DLNUM

Alarm can be triggered by following measuring cycles: all measuring cycles. Remedy: Check the number of additive offset and setup offset. Check parameter _DLNUM.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • Incorrect or missing _DLNUM parameter value in the active measuring cycle
  • DL (offset) number referenced in measuring cycle does not exist in machine offset table
  • Additive offset or setup offset count mismatch with configured _DLNUM value
  • Corrupted or improperly loaded measuring cycle program block
  • Parameter _DLNUM pointing to invalid memory location or offset range

Troubleshooting Steps

  1. 1Verify the _DLNUM parameter value in the current measuring cycle matches an existing offset number in the machine's DL offset table
  2. 2Check that additive offset and setup offset counts are correctly configured and match the _DLNUM reference
  3. 3Review the measuring cycle program syntax at the specified block number to ensure _DLNUM is properly declared and within valid range
  4. 4Clear the measuring cycle cache and reload the program from source; verify parameter inheritance and initialization
  5. 5If issue persists, perform a machine parameter backup, then reset _DLNUM to default value and reconfigure offset references

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.