Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 840D 61402 - Channel block: Probe collision, traversing path limitation through
Alarm 61402 occurs during CYCLE977 (Measure web/shaft) when the probe's traversing path in the working plane exceeds the software limit positions (MD 36010-36015: axis-specific software limit data), causing the probe to collide with the workpiece boundary during infeed. The NCK interpreter detects violation of programmed measurement coordinates against active software end positions before probe contact.
Siemens 840D 61402 - Channel block: Probe collision, traversing path limitation through
Channel block: Probe collision, traversing path limitation through
Siemens SINUMERIK alarm 61402: Channel block: Probe collision, traversing path limitation through. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 61402 occurs during CYCLE977 (Measure web/shaft) when the probe's traversing path in the working plane exceeds the software limit positions (MD 36010-36015: axis-specific software limit data), causing the probe to collide with the workpiece boundary during infeed. The NCK interpreter detects violation of programmed measurement coordinates against active software end positions before probe contact.
Safety
Causes and Fixes
Review CYCLE977 call parameters in NC program: check the measurement position coordinates (typically SX, SY for plane axes) against actual workpiece geometry and clamping limits. Use the HMI Diagnostics > Actual Values menu to verify current soft-limit values.
Access SINUMERIK 840D soft-limit machine data via NCK > Axis Data > MD 36010 (min) and MD 36015 (max) for affected axes. Compare programmed probe position against these limits; if probe coordinate exceeds limits, the alarm is justified.
Modifying soft limits without machine geometry verification can cause physical collisions.
Recalculate or adjust CYCLE977 measurement position to remain within active software limits. Document the safe measurement envelope based on workpiece setup and re-test with a dry-run (single block, reduced feed).
Clear alarm via NC > Alarms menu after correcting coordinates. Monitor probe approach in next cycle execution; use DIN/CCW probe diagnostic display to confirm probe retracts safely.