Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

61372

Siemens 840D 61372 - Channel block: selected meas.variant requires SPOS-capable

Channel block: selected meas.variant requires SPOS-capable

Alarm can be triggered by following measuring cycles: all measuring cycles. Remedy: Change measuring variant or check machine equipment.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • Selected measuring cycle variant requires SPOS (spindle positioning) capability that is not configured or enabled for the channel
  • Machine lacks hardware support for synchronized spindle positioning required by the chosen measuring variant
  • Measuring variant parameter mismatch between program requirements and actual machine configuration
  • SPOS functionality disabled or not properly initialized in the NC configuration
  • Incompatible measuring cycle selected for current spindle/channel setup

Troubleshooting Steps

  1. 1Verify machine equipment includes SPOS-capable spindle and confirm it is properly configured in the machine data and channel parameters
  2. 2Review the measuring cycle variant being called in block %2 and cross-reference against available variants that do not require SPOS capability
  3. 3Check NC configuration files and machine data to ensure SPOS is enabled for channel %1; consult machine manufacturer documentation for correct parameter settings
  4. 4Test with an alternative measuring variant that matches current machine capabilities; if alarm clears, confirm original variant requirements with setup
  5. 5If SPOS hardware exists but is disabled, enable it through appropriate configuration and reinitialize the channel

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?