Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

4022

Siemens 4022 - Axis : axis container switch not allowed: ext. work offset active

Axis: axis container switch not allowed: ext. work offset active

The axis container switch enable cannot be given because an external zero offset is active Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The axis container switch enable cannot be given because an external zero offset is active

Troubleshooting Steps

  1. 1The program must be aborted with the RESET key and the external zero point offset deselected before the container is advanced.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.