Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

310775

Siemens 310775 - Axis drive knee area and saturation area of valve characteristic

Axis drive knee area and saturation area of valve characteristic

The knee area and the saturation area of the valve characteristic overlap Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The knee area and the saturation area of the valve characteristic overlap

Troubleshooting Steps

  1. 1The knee area and the saturation area overlap if: - Positive quadrant: (MD 5465 + MD 5466) > MD 5486 - Negative quadrant: (MD 5468 + MD 5466) > MD 5488 Enter a valid combination in the above drive MD.
  2. 2Clear alarm with the RESET key in all channels. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.