Siemens 301719 - Axis drive power section data incomplete
This alarm occurs when the power section data for a drive is incomplete, typically due to missing or incorrect machine data (MD) settings for derating factors. Correct the relevant MD parameters to resolve it.
Siemens 301719 - Axis drive power section data incomplete
Axis drive power section data incomplete
The data for the power section are incomplete: - Operation of a power section with an FDD motor requires: MD 1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz) - Operation of a power section with an MSD motor requires: MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz) - Operation of a power section with a PE MSD motor requires: MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz) - MD 1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD) - MD 1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD) Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
This alarm occurs when the power section data for a drive is incomplete, typically due to missing or incorrect machine data (MD) settings for derating factors. Correct the relevant MD parameters to resolve it.
Safety
Causes and Fixes
Check alarm details
Note the axis and drive number in the alarm message to identify the affected component.
Verify machine data
Access MD 1178 and MD 1179 in the control parameters and ensure correct derating values are set for 8kHz operation.
Save and restart
Save the corrected parameters, reset the alarm, and restart the system to apply changes.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.