Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300714

Siemens 300714 - Axis drive power section code invalid

Axis drive power section code invalid

The code number of the power section entered in drive MD 1106: $MD_INVERTER_CODE (power section code number) does not match the power section in the drive configuration display (MD 13020: $MD_DRIVE_INVERTER_CODE) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The code number of the power section entered in drive MD 1106: $MD_INVERTER_CODE (power section code number) does not match the power section in the drive configuration display (MD 13020: $MD_DRIVE_INVERTER_CODE)

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Delete modified machine data (e.g. controller data).
  3. 3Reset the drive (delete the bootfile) and repeat the startup.
  4. 4Switch control OFF - ON. 2-723

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.