Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300711

Siemens 300711 - Axis drive monitoring cycle times of axes differ

Axis drive monitoring cycle times of axes differ

The monitoring cycle MD 1002: $MD_MONITOR_CYCLE_TIME must be identical for both axes on 2axis modules Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The monitoring cycle MD 1002: $MD_MONITOR_CYCLE_TIME must be identical for both axes on 2axis modules

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Modify MD 1002: $MD_MONITOR_CYCLE_TIME for both axes.
  3. 3Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.