Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300511

Siemens 300511 - Axis drive measuring function active

Axis drive measuring function active

The measuring function (e.g. frequency response measurement was active during the switching on operation (power supply start-up active). Illegal activation of the measuring function may have occurred internally Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The measuring function (e.g. frequency response measurement was active during the switching on operation (power supply start-up active).
  • Illegal activation of the measuring function may have occurred internally

Troubleshooting Steps

  1. 1Stop the measuring function - NCK reset
  2. 2Switch control OFF - ON