Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

300412

Siemens 300412 - Error when storing a file ( , )

Error when storing a file (,)

An attempt to save a data block, e.g. the result of a measuring function, in the file system has failed Control reaction: Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • An attempt to save a data block, e.g. the result of a measuring function, in the file system has failed

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Create more space in the file system.
  3. 3It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory.
  4. 4If these remedies do not work, it will be necessary to increase the number of files per directory or the size of the file system itself.
  5. 5To do so, proceed as follows: - Save all data - Change settings of machine data - 18280 $MM_NUM_FILES_PER_DIR - 18320 $MM_NUM_FILES_IN_FILESYSTEM - 18350 $MM_USER_FILE_MEM_MINIMUM - and, if necessary, of - 18270 $MM_NUM_SUBDIR_PER_DIR - 18310 $MM_NUM_DIR_IN_FILESYSTEM - Power On - Reload saved data
  6. 6Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.