Siemens 300502 - Axis drive maximum current monitoring of phase current R
The phase current R is greater than or equal to 1.05 times the maximum power section current MD 1107: $MD_INVERTER_MAX_CURRENT (transistor limit current) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Siemens 300502 - Axis drive maximum current monitoring of phase current R
Axis drive maximum current monitoring of phase current R
The phase current R is greater than or equal to 1.05 times the maximum power section current MD 1107: $MD_INVERTER_MAX_CURRENT (transistor limit current) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Safety
Common Causes
Troubleshooting Steps