Siemens 840D 21703 - Channel block axis touch probe not deflected, illegal edge
Alarm 21703 fires when the touch probe fails to detect a deflection state transition during measurement level 2 operations (MEAWA, MEASA, MEAC). The probe's initial deflection state matches the first programmed measurement edge, preventing the NCK from recording the required state change needed to capture valid measured values.
Siemens 840D 21703 - Channel block axis touch probe not deflected, illegal edge
Channel block axis touch probe not deflected, illegal edge
Siemens SINUMERIK 840D alarm 21703: Channel block axis touch probe not deflected, illegal edge. This alarm indicates a program or channel-level error on the SINUMERIK control. The part program or machine function cannot be executed as commanded.
Root Cause Summary
Alarm 21703 fires when the touch probe fails to detect a deflection state transition during measurement level 2 operations (MEAWA, MEASA, MEAC). The probe's initial deflection state matches the first programmed measurement edge, preventing the NCK from recording the required state change needed to capture valid measured values.
Safety
Causes and Fixes
Verify physical probe contact by manually triggering the probe stylus perpendicular to its axis and listening/feeling for the click. Check for bent, worn, or obstructed stylus preventing deflection.
Do not apply excessive force - probe stylus typically requires 500-800g deflection force.
Inspect probe connector and cable for corrosion or loose pins. Check cable continuity with multimeter between probe connector and machine spindle/tool holder interface per your machine's probe connection documentation.
Machine must be powered down and in manual mode before testing electrical continuity.
In MDI mode, execute G65 manual probe test cycle or use Diagnostics > Probing > Manual Test (path varies by control version) to observe probe signal state changes in real-time before launching measurement program.
Replace probe stylus or entire probe assembly if deflection test fails. Verify replacement probe part number matches original specification in machine documentation.