Siemens 17270 - Block call-by-reference: illegal variable

Block call-by-reference: illegal variable

Machine data and system variables must not be transferred as call-by-reference parameters Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Machine data and system variables must not be transferred as call-by-reference parameters

Troubleshooting Steps

  1. 1Modify NC program: Assign the value of the machine data or of the system variable to a program-local variable and transfer this as parameter.
  2. 2Clear alarm with NC START or RESET key and continue the program