Siemens 16932 - Conflict when activating user data type
The "activate user data" function (PI service _N_SETUDT) modifies a data block (tool offset, settable zero offset or base frame) which is also written by the NC blocks in preparation. In the event of a conflict, the value entered by the HMI is reset. Parameter specifies which data block is affected: 1: Active tool offset 2: Base frame 3: Active zero offset Control reaction: Alarm display.
Siemens 16932 - Conflict when activating user data type
Conflict when activating user data type
The "activate user data" function (PI service _N_SETUDT) modifies a data block (tool offset, settable zero offset or base frame) which is also written by the NC blocks in preparation. In the event of a conflict, the value entered by the HMI is reset. Parameter specifies which data block is affected: 1: Active tool offset 2: Base frame 3: Active zero offset Control reaction: Alarm display.